What tests and checks are involved in a boiler service?
Our service engineer will do 19 detailed checks and tests when carrying out a gas boiler service. All visual checks and tests are in accordance with Irish Standards 813:2017 as per the National Standards Authority of Ireland for Domestic Gas Installations.
The following checks and tests will be carried out:
Number | Check |
1 |
Check the location of the appliance, its condition and electrical controls |
2 | Inspect flue thoroughly |
3 | Check ventilation meets legal requirements |
4 | Conduct electrical safety tests |
5 |
Check accessibility, functionality and condition of isolating valves |
6 |
Inspect / clean fan unit and evaluate performance and functionality |
7 |
Inspect / clean heat exchanger as per manufacturer’s instructions |
8 | Inspect / clean / adjust main and pilot burners and injectors |
9 | Check / clean / adjust ignition and ionisation electrodes |
10 | Check flame picture |
11 | Check temperature control |
12 | Check operation of boiler safety devices |
13 | Check appliance gas rating |
14 | Conduct burner pressure tests |
15 | Sample air intake analysis |
16 | Sample flue gas analysis to ensure safe operation |
17 | Conduct appliance gas safety tests |
18 | Adjustment time and temperature controls as required |
19 |
Complete RGII appliance conformance certificate and leave copy with customer |
Please note: Our service engineers may also complete various other tests as required for specific types of gas boilers, as per best practice and the manufacturer’s guidelines.